Locking Compression Plates Systems
Showing 1–20 of 36 results
Trauma_LCP Systems (Titanium) Distal Lateral Tibial Locking Plates(I)
Application:Fractures of medial proximal tibia plateau
Spec:117mm*7holes-225mm*13holes
Material: Titanium
Matching Screw:
?3.5 Cortical Screw
?3.5 Locking Screw
?3.5/?4.0 Cancellous Screw
Trauma_LCP Systems (Titanium) Distal Medial Tibial Locking Plates (III)
Application:Fractures of medial proximal tibia plateau
Spec 128mm*4holes-240mm*11holes
Material: Titanium
Matching Screw:
?3.5 Locking Screw;
?3.5 Cortical Screw
Trauma_LCP Systems (Titanium) Limited Contact Tibial Metaphysis Plates
Application:Tibial metaphyseal fractures.
Spec 154mm*5holes-298mm*13holes
Material: Titanium
Matching Screw:
?3.5/5.0 Locking Screw;
?3.5 Cortical Screw;
?3.5 Cancellous Screw
Trauma_LCP Systems (Titanium) Olecranon Hook Locking Plates
Application: Fractures of distal humerus.
humerus and distal tibia
Spec :71mm*3holes-155mm*10holes
Material: Titanium
Matching Screw:
: ?3.5 Locking Screw;
?3.5 Cortical Screw
Trauma_LCP Systems (Titanium) Buttress Locking Plates (L-shape)
Application::Fractures of lateral proximal tibia
Spec:68mm*3holes-180mm*10holes
Material: Titanium
Matching Screw:
?5.0 Locking Screw
?4.5 Cortical Screw
Trauma_LCP Systems (Titanium) Buttress Locking Plates (T-shape)
Application:Fractures of medial proximal tibia plateau
Spec :68mm*3holes-180mm*10holes
Material: Titanium
Matching Screw:
?5.0 Locking Screw
?4.5 Cortical Screw
Trauma_LCP Systems (Titanium) Calcaneal Locking Plate (VI)
Application: Calcaneus Fractures
Thickness: 2mm
Trauma_LCP Systems (Titanium) Calcaneus Locking Plates(I)
Application:Calcaneus Fractures
Spec:11holes-15holes
Material: Titanium
Matching Screw:
?3.5 Locking Screw;
?3.5 Cancellous Screw
Trauma_LCP Systems (Titanium) Calcaneus Locking Plates(II)
Application:Calcaneus Fractures
Spec14holes
Material: Titanium
Matching Screw:
: ?3.5 Locking Screw;
?3.5 Cancellous Screw
Trauma_LCP Systems (Titanium) Calcaneus Locking Plates(III)
Application:Calcaneus Fractures
Spec13holes
Material: Titanium
Matching Screw:
?3.5 Locking Screw;
?3.5 Cancellous Screw
Trauma_LCP Systems (Titanium) Calcaneus Locking Plates(V)
Application:Calcaneus Fractures
Spec8holes
Material: Titanium
Matching Screw:
?3.5 Locking Screw;
?3.5 Cancellous Screw
Trauma_LCP Systems (Titanium) Clavicle Diaphysis Locking Plates
Application: Fractures of clavicle.
Spec58mm*5holes-135mm*12holes
Material: Titanium
Matching Screw:
:?3.5 Locking Screw;
?3.5 Cortical Screw
Trauma_LCP Systems (Titanium) Clavicle Hook Reconstruction Locking Plates
Application: Fractures of clavicle.
Spec51mm*2holes-95mm*6holes
Material: Titanium
Matching Screw:
?3.5 Locking Screw;
?3.5 Cortical Screw
Trauma_LCP Systems (Titanium) Cloverleaf Plate
Application: Fractures in proximal
humerus and distal tibia
Spec 88mm*3holes-136mm*6holes
Material: Titanium
Matching Screw:
3.5 Cortical Screw
Locking Screw
3.5/4.0 Cancellous Screw
Trauma_LCP Systems (Titanium) Distal Femoral Condylar Buttress Locking Plates
Application:Used to support the distal femur in case where
the fracture site is comminuted.
Spec :98mm*3holes-258mm*13holes
Material: Titanium
Matching Screw:
?5.0 Locking Screw
?4.5 Cortical Screw
Trauma_LCP Systems (Titanium) Distal Lateral Femoral Locking Plates
Application::Used to support the femur in
case where the fracture site is comminuted.
Spec :116mm*3holes-316mm*13holes
Material: Titanium
Matching Screw:
?5.0 Locking Screw
?4.5 Cortical Screw
Trauma_LCP Systems (Titanium) Distal Lateral Fibular Locking Plates
Application: Fractures of distal lateral fibula
Spec 55mm*2holes-151mm*10holes
Material: Titanium
Matching Screw:
: ?3.5 Locking Screw;
?3.5 Cortical Screw
Trauma_LCP Systems (Titanium) Distal Lateral Humeral locking Plate (I), Combined-lock
Application:Fractures of lateral distal humerus
Spec 67mm*3holes-139mm*11holes
Material: Titanium
Matching Screw:
3.5 Cortical Screw
2.7/3.5 Locking Screw
4.0 Cancellous Screw
Trauma_LCP Systems (Titanium) Distal Lateral Humeral locking Plate,Combined-lock
Application:Fractures of lateral distal humerus
Spec 67mm*3holes-139mm*11holes
Material: Titanium
Matching Screw:
3.5 Cortical Screw
2.7/3.5 Locking Screw
4.0 Cancellous Screw
Trauma_LCP Systems (Titanium) Distal Lateral Tibial Locking Plates (II)
Application:Fractures of medial proximal tibia plateau
Spec 86mm*3holes-246mm*13holes
Material: Titanium
Matching Screw:
?5.0 Locking Screw
?4.5 Cortical Screw