Single Result

Sort by:
  • Progetti Rescue Life 9 is designed for out-of-hospital and hospital use. Lightweight, ergonomic, attractive and robust portable device. Rescue Life 9 provides complete monitoring of parameters like 12 channels ECG, HR, SpO2, NIBP, Temperature and EtCO2. Synchronized cardioversion and external pacemaker in fixed or demand mode. Three operating modes: manual, AED, Advisory. Capnography waveform. Auto-test mode verifies device functions, battery status and charge-discharge system with real-time data management and report printing. The IPX4 permits operations under adverse climatic situations. Rescue Life 9 Technical Specification: General requirements • Dimension: 335x225x360 mm • Weight: 6.5 kg with dual batteries • Electrical: AC 100-240 VAC, 50/60 Hz • Rechargeable Lithium-ion batteries: 15.0 V – 3.2 Ah • Battery Operation Time: >5 hours, with 1 battery >10 hours with 2 batteries • Charge Time: Max. 3 hours • Capacity: 150 shocks with 1 battery or 300 shocks with 2 batteries at 230J fully charged • Software: Voice and text multi-language • Memory: Internal flash for ECG data, events and usage review Defibrillation • Waveform: Biphasic Truncated Exponential (BTE), HiCAP technology (Large storage capacitor) • Impedance: Compensated, range 25-200 Ohm • Charge time: 6 sec for 230 J with the battery fully charged AED mode • Energy: Fixed energy at 200 J • Protocol: ERC 2015 CPR Guidelines with voice and text prompts • Shockable rhythms: VF with amplitude > 0.15 mV and VT with rhythm >150 bpm • Sensitivity: Shockable rhythm -VF > 95%, -VT > 75% • Specificity: According to ERC 2015, • Normal sinusoidal rhythm > 99% • Asystole and other non-shockable rhythms > 99% Manual mode • Energy range: 1-230 J (from 1-10 J in 1 J steps; from 10 to 230 J in 10 J steps) • Commands: Multifunction trim knob • Charge and shock button in the front panel • Operating mode: EC G «R» wave synchro or async mode • Indicators: Battery and main led indicators Display • Type: High contrast TFT colour LCD 8” (800Ă—600 dots) • Information: ECG traces, SpO2, NIBP, EtCO2, TEMP, Heart Rate indicator, filters, alarms and the batteries status • Display mode: Can select 3, 6, 12 ECG leads Ecg monitoring • Bandwidth: 0.05 – 120 Hz (-3 db) in diagnostic mode 0.6 – 40 Hz (-3 db) in monitoring mode • CMRR: > 98 dbv Input impedance: > 50 Mohm • Input: Patient cable 5 leads (I, II, III, aVL, aVF, aVR, V) – standard Patient cable 10 leads (I, II, III, aVL, aVF, aVR, V1…..V6) – optional • Speed: 5, 10, 25, 50 mm/sec • Filters: 50/60 Hz, EMG Filter, base line • HR range: 20-300 bpm (~2%), digital readout on the display • Alarm: HR max settable 250 bpm; HR min 20 bpm SpO2 (only 55505-55512) • SpO2 range: 0-100% HR range: 30-250 bpm • Accuracy: 70-100% ~2% for adults with finger clip sensor • Alarm: Adjustable min 50% Temperature • Probe type: YSI400 compatible • Range: 0 to 50° C • Resolution: ±0.1° C Standard • IEC 60601-2-4; IEC 60601-1; IEC 60601-1-2; IEC 63204, IEC 62366-1 • CE Mark EEC 93/42: Medical device, Class IIb • Isolation: ECG type CF, Defibrillation type BF • Waterproof: Class IP54 Click Here To Download Catalogue
    Sku: ZN2023034

    RESCUE LIFE 9 AED DEFIBRILLATOR with Temp, Spo2, Pacemaker

    Read more
    Quick View