Medica’s EasyStat blood gas analyzer is utilized to measure PCO2, pH, Na+, CA++, K+, CI- and Hct, and it is able to calculate additional parameters. The digital keypad enables information to be entered and integrated with patient results. This information includes patient parameters, FIO2, patient temperature, patient ID, %FIO2 drawing site and other information. EasyStat is able to provide precision and high performance in the healthcare environment, whilst focusing on being able to deliver efficient and economic sample results.
Features:
EasyStat’s compact format and modular design reduces space requirements and maintenance.
It has an economical operation and low cost per sample due to the disposable electrodes and reagent module.
The liquid calibrants are packaged in a single reagent module and all analyzer components are combined into simple modules.
The user is guided through the analyzer operation by the simple menus guide.
Â
Click Here To Download Catalogue
EasyLyte is a completely automated, microprocessor-controlled analyzer that uses advanced ISE (Ion Selective Electrode) technology to make electrolyte measurements.
Combining the advanced technology of hematology analysis and latex immunoturbidimetry, BC-5390 CRP/BC-5310 CRP requires only 35ÎĽl blood from a single blood tube, to simultaneously provide results of WBC 5-part differentiation and FR-CRP at a throughput speed of 60 samples/hour.
C-reactive protein (CRP) is an important diagnostic parameter to detect inflammation, monitor progress of inflammatory process or effectiveness of therapeutic treatment. The availability of CRP and WBC parameter data simultaneously can help with prompt differentiation of bacterial infections from viral infections.
Features
Dual CRP Analysis Channels for High Throughput
Dual CRP analysis channels working together save waiting time of consecutive tests between hematology and CRP test, enabling a CBC+DIFF+CRP throughput of up to 60 samples per hour, which is the fastest in the industry for the same mode of measurement.
Latex Immunoturbidimetric Technology
Advanced and proven Latex Immunoturbidimetric technology plus two reagents can well guarantee the analyzing accuracy in fast dual-channel CBC+DIFF+CRP test.
Powerful reagent
New powerful reagent improves the 5-part WBC differentiation ability (especially in samples with high number of Eosinophils) and ability to process aged samples (maintained at ambient temperatures for up to 24 hours)
NRBC parameters and flag
BC-5390 CRP/BC-5310 CRP can flag “NRBC” research parameters called NRBC# and NRBC%, which represent respectively the number and ratio of the nucleated red blood cells, facilitating doctors with important diagnostic inferences.
NLR parameter in each CBC+DIFF
Neutrophil-to-lymphocyte ratio (NLR) is calculated by dividing neutrophil count by lymphocyte count, usually from peripheral blood sample.
In laboratory medicine, NLR is used as a marker of subclinical inflammation.
According to clinical studies, NLR can be used as a prognostic factor of severe illness in COVID-19 patients.
Product Specification
Model Name/Number
BC-6200
Operation Mode
Fully Automatic
Usage/Application
Hospital
Brand
Mindray
Display
Digital
Throughput
110 Tests per hour.
Screen Type
Touch Screen
Product
At Mindray, we seek to understand the needs of every customer, and deliver tailor-made solutions. In today’s laboratories, lab managers are looking for an analyzer with greater clinical values, such as higher flagging efficiency to reduce the ratio of microscopic examination, NRBC/RET/body fluid results generated in a small-footprint system, among others, all within limited budget. Mindray BC-6200 fulfills all these clinical requirements and exceeds your expectations!
FeaturesWith the newly designed opticals and reagent systems, the SF Cube technology can help doctors to better differentiate the clusters of cells, which is the key to revealing more abnormal cells.NRBC result in every CBC In WNB scattergram, BC-6200 provides NRBC, Basophils and WBC-N* results. It means that the actual number of NRBCs can be measured in routine CBC, if they are present in the sample.Basophils are counted in this counting channel with NRBC results. Basophil and NRBC results are generated on BC-6200 without extra reagent or cost.
More accurate RET and PLT-O resultÂ
By utilizing the new fluorescent dye, the reticulocytes and platelets are more specific stained with stronger fluorescent signal, that brings a more accurate reticulocyte and platelet results.
Automatic Rerun & ReflexÂ
Should the sample results trigger the criteria, the autoloader of BC-6200 can return the sample racks for an automatic rerun or reflex check.
Less testing timeÂ
BC-6200 can load up to 50 samples at a time and offers a throughput of up to 110 tests per hour.
Low sample volumeÂ
BC-6200 requires less sample volume as well as reagent consumption. For a CBC+DIFF test with NRBC result, BC-6200 only requires 80ÎĽL of whole blood and 35 ÎĽL of capillary blood.
40 reportable parameters, 19 research parameters, 4 scattergrams (3D), 7 scattergrams (2D), 3 histograms;
SF Cube Cell Analysis Technology (flow cytometry combined with laser scatter and fluorescence) and Focusing Flow-DC method;
Autoloader capacity of 100 sample tubes with random & continuous loading;
Throughput up to 125 samples per hour (CBC+DIFF);
Maximum sample consumption of 200 ÎĽl in autoloader mode;
Body fluid analysis in manual mode (cerebrospinal fluid and serous fluids -peritoneal and pleural);
Data storage capacity of 100,000 patient results including all numeric and graphical information;
Ability to flag abnormal cells based on customizable decision rules;
Re-exam rules to pull out abnormal samples for further checking;
Supports bi-directional LIS connection with communication protocols HL7 or ASTM;
No daily maintenance.
Product Specification
Automation
Fully Automatic
Brand
Mindray
Usage/Application
Laboratory
Differential Type
5-Part
Number Of Chambers
2
Number Of Parameters
HCT
Parameters
RBC
Model Name/Number
BC700 Series
User Input
Touch
Type Of Blood Analyzer
Hemoglobin Analyzer
Sample Mode
Whole Blood, Capillary, Pre-Diluted
Calibration
7 Point
Chamber Type
Dual Chamber
Product
We Are Excited to Announce that We Are Going to Launch a New Breakthrough Innovation, the Bc-700 Series Auto Hematology Analyzer Which Incorporates Both Cbc and Esr Analysis.
The Bc-700 Series Is by Far One of The Most Powerful, Innovative and Compact All-In-One Hematology Analyzers in The Market. with Its Newest Parameters, the Analyzer Provides a High-End Analysis Platform for Small to Medium-Sized Laboratories, Allowing Mindray to Take Another Huge Step Towards Fulfilling Our Mission, Healthcare Within Reach.
Product Specification
Automation
Fully Automatic
Brand
Mindray
Model Name/Number
BS 430
Assays
Clinical Chemistry
Power Supply
230 V
Reaction Cuvette
Flow Cell
Storage
250000 Samples
Features
Seamless Integration
Usage/Application
Lab
Wavelength
3000nm
Number Of Reagent Positions
1
Weight
100kg
Frequency
50 Hertz
Wattage
40 Watt
Product
Uniform reagent package
The reagent package is applicable to Mindray Chemistry Analyzers including BS-120, BS-200, BS-200E, BS-230, BS-240, BS-240Pro, BS- 360E and BS-430.
Good for Reagent management
Customer breakthrough – no need to introduce one more reagent system
Reagent forecast – same regent package with MR bench-top analyzers, lower forecast fluctuation
End-user preference – better reagent management, avoid reagent waste
Potential possibility for back-up analyzers
For end-user with BS 430, there’s possibility of adding bench-top analyzer as back-up.HbA1c smart sampling
BS-430 chemistry analyzer utilizes HbA1c smart-sampling technology, which allows onboard automatic hemolysate preparation for whole blood samples, thus achieving shorter turnaround time (TAT) and eliminating any biohazardous risks or any errors by manual operation.
Mindray’s new BS-600M Chemistry Analyzer provides a complete package to help you grow your lab. It has high throughput with industry-leading small footprint, advanced automated sample loading, whole blood HbA1c testing as well as improved ISE with lower consumption. Combining these robust features with our full panel of original manufacturer chemistry reagents will empower your lab with increased productivity and efficiency as well as reduced costs.
The Powerful yet Efficient BS-600M Chemistry Analyzer provides a complete package to help you grow your lab. This groundbreaking analyzer has:
high throughput with industry-leading small footprint,
advanced automated sample loading,
whole blood HbA1c testing,
improved ISE with lower consumption.
Combining these robust features with our full panel of original manufacturer chemistry reagents will empower your lab with increased productivity and efficiency.
Though with a compact size, it has achieved a host of advanced functions never before found on a like product in the market, making it an optimal chemistry solution for small laboratories and a back-up tool for mid-to-high end laboratories.
Discrete, random access, fully automated
200 tests per hour, up to 400 tests per hour with ISE
80 Reagent and 40 Sample Position
Minimal reagent volume 100ul
Refrigerated reagent & sample compartment
Automatic probe cleaning, liquid level detection & collision
protection
Whole blood testing function for HbA1c
Automatic dilution for abnormal sample
8-step auto wash system 80 semi-permanent cuvettes
High efficiency stand along mixing bar
Inbuit barcode reader
Bi-directional LIS interface
The Mindray CAL 6000 defines a new generation of cellular analysis line. By combining BC-6000 or BC-6200 auto hematology analyzers and SC-120 Slide Maker & Stainer, CAL 6000 offers flexible configurations which have throughput of up to 220 tests per hour and 120 slides per hour.
CAL 6000 has flexible configurations which can meet different labs with different requirements.
Large loading area can load 100 samples at the same time.
The patented “two-way loading” technology of the track enables smart distribution of workload and enhanced efficiency and productivity.
Should the sample results trigger the criteria, the sample rack can automatically step back for a “rerun” or “reflex” check.
Product
CL-1200i is a robust and simple-to-use chemiluminescence analyzer with a throughput of up to 180 tests per hour. Though in a small benchtop package, it has a large onboard capacity of 25 reagents and 60 samples, and supports non-stop refill of samples, reagents and consumables during testing. By integrating the reliable CLIA technology with latest electrical and software improvement, CL-1200i enables easy operation and brings confident diagnosis faster than ever.
Features:
· One of the fastest benchtop chemiluminescence analyzers
· Large onboard capacity in a small benchtop package
· Swing arm and touch screen for easy operation
· Non-stop sample loading and off-loading
Product
A floor-standing, fully automatic, chemiluminescence immunoassay system offering up to 240 tests per hour with ALP-AMPPD principle.
Features
High test throughput up to 240 T/H
Large capacity for sample (300 sample positions) and reagent processing (36 reagent positions)
User-friendly software interface
Flexible connection with BS-800M/BS-2000M chemistry system
Product
SAL 6000 Modular System delivers fast throughput and seamless integration of CL-2000i Chemiluminescence Immunoassay System and BS-800 Modular System. In conjunction with the SPL 1000 Sample Processing line, this scalable platform not only provides optimized workflow, it also offers satisfactory operator experience.
Features
Seamless integration, workflow optimization
Uniform software interface, easy of operation
One tube sampling, flexible to test
Technology and quality heritage
Flexible scalability, on-site upgrading
Comprehensive test menu
Designed for POC Testing
Portable handheld
Large, easy-to-read LCD
Optional test devices minimize contamination
Accurate
Precise results equivalent to laboratory analyzers
Wide Hb measurement range of 4.5 – 25.6 g/dL
Calculated Hct range of 13 – 75%
Quick & Convenient
Results in < 15 seconds
Auto-calibration
Stores up to 1,000 results
Fast data transfer via Mini USB port