Haier HR40-IIA2

Product Specification

Class
Class II

Product Type
Type A2

Model
HR40

Operator
1

Interior Dimensions
1200*610 *680 mm

Overall dimensions
1360*780 *2200 mm

UV light
Greater Than 30w

Noise
Less than 62dB(A)

IIIumination
Greater Than 800Lx

Inflow Air Velocity
Greater Than 0.6m/s

Downflow Air Velocity
Greater Than 0.3+- 0.02m/s

Cleanliness
CLASS 100@ Greater Than 0.5um

Product

Other Details:

Product Feature: Fission?structure : The front panels are detachable and easier to remove for filter and filter. Visible windows: with antiultraviolet toughened glass and the height of glass can be adjustable. If the height is higher than safe level, the audible and visual alarm will be opened.
The cabinet: all manufactured by 304??? stainless steel material and the left, right and back bins of cabinet are manufactured together with arc angle will make easier to clean the side of cabinet.
Cabinet feature: Contaminated?Pressure Plenum: Negative Unitized drain pan beneath the work surface allows best arm position the user?s lap.
The airflow design creates a more impenetrable air barrier or momentum air curtain at the front of the cabinet, increasing the cabinet?s protective capabilities and avoiding cross infection.
This kind of design standard is comply with NSF4911 standard. With strong wind form the draught intake in side of cabinet, which will clear the round airflow up in lateral cabinet and prohibit the moving of contamination.
Ultra-high efficiency filter system: input and output of air will be filtrated by ULPA filter and its efficiency is more than 99.999%. the pressure sensor will watch the working condition of filter from time to time and alarm the operator if the operator if the pressure is over the setting value.
Ultraviolet light safety: the UV light cannot be opened when the fan, visible window and fluorescent light are running.
Interlock function for two fans ( blower and exhaust fan ):
When the exhaust fan stops, the blower will stop automatically and alarm device will begin to work. When the blower stops, the exhaust fan will continue to work and the alarm system will indicate the fault of blower.
Displaying data in the screen:?Air-exhaust value ( m3/h ) the velocity of air laminar flow ( m/s ) counter for exhaust fan counter for blower.
Safety control system:?Alarm for low air exhaust value
Alarm for low air-velocity of down laminar flow
Alarm for fault of exhaust fan
Alarm for closing condition of visible window
When the visible windows is opened, the UV light will be closed automatically.
When the fluorescent light is on working, the UV light will be closed automatically.
When the blower begin to work and then the UV light will be off after air laminar flow is created.
The blower will be off automatically if the exhaust fan happens some trouble.
The exhaust fan will increase his rotate speed automatically in order to keep the working space in negative pressure inside cabinet in case something wrong happens with the blower.
Microprocessor will counteract the gradually increased resistance in filter.
It will keep air inflow and downflow in normal condition under any conditions

SKU: ZN000129 Categories: , , Tag:
Description

Description

Description

Product Specification

Class Class II
Product Type Type A2
Model HR40
Operator 1
Interior Dimensions 1200*610 *680 mm
Overall dimensions 1360*780 *2200 mm
UV light Greater Than 30w
Noise Less than 62dB(A)
IIIumination Greater Than 800Lx
Inflow Air Velocity Greater Than 0.6m/s
Downflow Air Velocity Greater Than 0.3+- 0.02m/s
Cleanliness CLASS 100@ Greater Than 0.5um

Product Description

Other Details:

  • Product Feature: Fission structure : The front panels are detachable and easier to remove for filter and filter. Visible windows: with antiultraviolet toughened glass and the height of glass can be adjustable. If the height is higher than safe level, the audible and visual alarm will be opened.
  • The cabinet: all manufactured by 304??? stainless steel material and the left, right and back bins of cabinet are manufactured together with arc angle will make easier to clean the side of cabinet.
  • Cabinet feature: Contaminated Pressure Plenum: Negative Unitized drain pan beneath the work surface allows best arm position the user?s lap.
  • The airflow design creates a more impenetrable air barrier or momentum air curtain at the front of the cabinet, increasing the cabinet?s protective capabilities and avoiding cross infection.
  • This kind of design standard is comply with NSF4911 standard. With strong wind form the draught intake in side of cabinet, which will clear the round airflow up in lateral cabinet and prohibit the moving of contamination.
  • Ultra-high efficiency filter system: input and output of air will be filtrated by ULPA filter and its efficiency is more than 99.999%. the pressure sensor will watch the working condition of filter from time to time and alarm the operator if the operator if the pressure is over the setting value.
  • Ultraviolet light safety: the UV light cannot be opened when the fan, visible window and fluorescent light are running.
  • Interlock function for two fans ( blower and exhaust fan ):
  • When the exhaust fan stops, the blower will stop automatically and alarm device will begin to work. When the blower stops, the exhaust fan will continue to work and the alarm system will indicate the fault of blower.
  • Displaying data in the screen: Air-exhaust value ( m3/h ) the velocity of air laminar flow ( m/s ) counter for exhaust fan counter for blower.
  • Safety control system: Alarm for low air exhaust value
  • Alarm for low air-velocity of down laminar flow
  • Alarm for fault of exhaust fan
  • Alarm for closing condition of visible window
  • When the visible windows is opened, the UV light will be closed automatically.
  • When the fluorescent light is on working, the UV light will be closed automatically.
  • When the blower begin to work and then the UV light will be off after air laminar flow is created.
  • The blower will be off automatically if the exhaust fan happens some trouble.
  • The exhaust fan will increase his rotate speed automatically in order to keep the working space in negative pressure inside cabinet in case something wrong happens with the blower.
  • Microprocessor will counteract the gradually increased resistance in filter.
  • It will keep air inflow and downflow in normal condition under any conditions
0/5 (0 Reviews)
Reviews (0)

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Vendor Info

Vendor Information

  • No ratings found yet!
More Products

AS20L

Mobile and fixed models; fixed model is special mounted our company?s infant incubator;
LED Bulb;
Timer to count phototherapy time;
Angle of lamp module can be adjusted (for mobile model);
Height of lamp module can be adjusted (for mobile model);
Wheels can be locked (for mobile model).

Mindray WATO EX-20 Anasthesia Machines

The main unit includes a Ventilator, mechanical low meters, breathing circuit with 1 CO2 absorber,1 drawer, 1 lithium battery (90 min) and pipeline pressure gauges.
Has a colour LCD screen size of 7 inch
Volume controlled ventilation with a tidal volume of 40 ? 1500 ml
Classical low meters for O2, N2 and Air
Support up to 2 vaporizer positions (ACGO) that allow you to use 3rd party semi-open circuits
Backup batteries support up to 150 min continuous work
Intelligent alarm management, e.g. permanent, silent volume/apnea
Besides Volume, there is VCV, which can be assisted in-patient once the operation has ended.
Has an electronically controlled, pneumatically driven ventilator.
Breathing circuit fully autoclavable at 134 c and nature latex free
Easy to disassemble and assemble all the components of the breathing circuit hence making it convenient for cleaning and maintenance purposes

SONICAID

Outputs

Loudspeaker 350mW rms typical Headset
10mW total (32 Omega stereo headset)

Fetal Health Rate

Display 3 digit FHR, Pulse/Signal quality
Battery Low
Accuracy <+ 2 bpm over 100-180 bpm Unique design Easy to use Water proof probe as standard Fetal Heart Rate Display

Cellular Blankets

These are plain fabric bedspreads, good appearance, only suitable for summer, blanket is needed, easy to wash and iron, easy to dress on the bed, easy to fold and pack the ?nishing binding is thin it eliminates bacteria and the colours are soft.
Fabric: 100% Cotton | Size: 200cm X 200cm
Cellular Blankets: Colours available: White, other coloursavailable on order. Life span: 1 ? 2 years on regular wash. Monogramming can be done on request at an extra cost.

Olympus CX33

Product Specification

Model
CX33

Condenser
NA1.25/ W.D.- (4 X ? 100 X)

Focusing
Stage Focus

Brand
Olympus

Observation Method
Brightfield,Darkfield

Illuminator
LED Lamp

Revolving Nosepiece
Standard Type

Observation Tubes
Tube Inclination Angle 30Degree

Product

Matching up with the ever increasing requirements of the customers, our company is engaged in providing?Olympus CX33 Biological Microscopes.

Trauma_LCP Systems (Titanium) Clavicle Diaphysis Locking Plates

Application: Fractures of clavicle.

Spec58mm*5holes-135mm*12holes

Material: Titanium

Matching Screw:

:?3.5 Locking Screw;

?3.5 Cortical Screw