353–368 of 1870 Results

Sort by:
  • KT88-3200 Digital Brain Electric Activity Mapping collects EEG signal with electrodes, via integrated amplification, A/D transformation, PC auto-analysis, FFT, to form electroencephalogram that displays with color depth. The product is applicable for checking such diseases as epilepsy, intracranial inflammation, cerebrovascular diseases and brain tumors. Features: Method of 10/20 electrodes placement under international standard system, leads can be changed during replaying. Support different types of combined leads during sampling. Adopt bioelectricity amplifier for distilling brainwave, continuous recording time can be up to 24 hours, integrated full-automatic calibration system. Powerful playback function: amplitude and display speed are adjustable. The special subdividing time line divides the waveform in one second into 5 parts, which is easy for doctors to look over the waveform. Digital filter system can be set as required, providing different window types EEG signal clipping function, analyze and store any section of EEG wave, and select several waveform segments for automatically analyzing and distilling to different parameters. Electronic frequency ruler, convenient to measure the basic information of any appointed EEG waveform. With partial enlarging window, accurate measurement of EEG period, amplitude and frequency, which can be adjusted according to personnel judgment. Mark EEG wave under the events of opening eyes, closing eyes and flashing with different colors, and user-defined events can be added, waveform color for evoked event can also be set freely, ensures that the waveform in corresponding time can be rapidly found by event name during case playback. Powerful automatic analysis function, can carry through the power spectrum analysis and pathologic wave detection for appointed waveform. Many graphs can be displayed in the same screen, including kinds of BEAM, numerical BEAM, compressed spectrum graph, trend graph, and so on. Professional isolation transformer, dual power supply isolation system and optoelectronic data transmission to ensure security. Use USB interface to transmit data which just need to be inserted. Multifunctional flash stimulator of USB interface, and flashing can be controlled manually or automatically. A flash stimulation scheme can be set and performed in the process of sampling. Perfect case management function, provides many means for research and quick statistic information; convenient case export and import function, and stores with MO or CD-RW disk, which is easy for data research. Integrative image and character report, report can be edited in mode and switched to Word document. Case files can be transformed into EDF and BDF data format, convenient for data exchange, academic exchange and further analysis. System parameters and display modes can be set as required, which meets different user’s requirement. Add marks and annotations to the waveform designated, which can rapidly find the waveform in that time by marks. Optional video function: USB camera is easy to install, convenient to use and exact to record. With flexible playback function, which can browse the waveform of any time along with the corresponding isochronous sampled image. SpO2 function is optional. Technical Specifications: 32 channels of EEG Sampling rate: 200 dots/s Accuracy: 12bit Input impedance: ≥10MΩ Patient leak current: < 10µA Noise level: ≤5µVp-p CMRR: ≥90dB Magnification multiple: 10000 Filter constant: all digital and free enactment Display speed(paper speed): 5, 10, 15, 30, 60, 120 mm/s Amplitude: 1, 1.5, 2, 3, 5, 7.5, 10, 12, 15, 20, 30, 50 mm/50µV Playback speed:1 time, 2 times, 3 times, 10 times, 20 times, 40 times, 60 times 50Hz interference suppression: ≥30dB Safety type:Class II, type BF applied part Accesories: EEG lead EEG electrode Data line Headgear Strobe light Strobe light power supply PC software CD User Manual Earth wire EEG bracket Aluminum block Click Here To Download Catalogue
    Sku: ZN2023204

    Contec KT88-3200 Electroencephalogram (EEG) Machine

    Read more
    Quick View
  • The high-acuity Neurofax EEG system is extremely intuitive. Its user-friendly software features a wide range of functions including record, playback, and quantitative data analysis. As a standard examination in neurology, electroencephalography is used in many scenarios – from routine diagnostics to critically ill patients, or neuromonitoring in the ICU. The Neurofax EEG system is built to cover all aspects of diagnostics, delivering innovative functionality, high signal quality, and durability to ensure efficiency – all while remaining simple to use. Features: Polaris.com, a powerful data management system, supports the straightforward administration and organization of diagnostic data. Modern communication interfaces (HL7 and GDT/BDT) enable integration into hospital and practice information systems. Digital Video Software allows synchronized digital video for EEG systems using webcam, professional HD camera, or picture-in-picture as per requirements. EEG Mapping, offers amplitude with spectral and frequency online mapping during acquisition, even with single channels and montages. Spike and Seizure Detection Software with a high sensitivity and a stunningly low false positive rate. Polysmith* combines sleep analysis software with recording devices to provide quick and precise data analysis – for a complete PSG solution customized to individual needs. EEG Trend Program converts EEG signals into clear trend graphs making them easy to interpret (aEEG, DSA, CSA, Power FFT). Smart vital signs interface for holistic multimodality assessment of patient, with capability to pull up 8 channels from bedside monitors Live View Panel offers intuitive real-time management of diverse neuromonitoring data from a centralized location. Amplifier: high-quality amplifier with 38 to 256 channels realizes wide-band EEG recording from slow shift to fast ripple. Brain function mapping system: a comprehensive and sophisticated system for brain function mapping reduces timeconsuming procedures by combining cortical stimulation, easy switch between stimulation and recording, and a brain function mapping report all in one place. EEG scope: data reviewer that allows review of previous EEG while monitoring, acquiring, and opening up to 4 EEGs at the same time. 3D voltage mapping: whole head maps offer a complete overview and better interpretation of the topography of EEG abnormalities. Customizable Main Menu that allows registration of examination protocol buttons on the main menu. Each button has user-defined settings for an examination which can be adjusted for different examination conditions and methods Note Window offers to save up to 1,000 sections of waveforms for comparison by dragging and dropping. Up to 100 copied waveforms can be registered as sample data for comparison with other patients or teaching purposes. NeuroReport, which is integrated in all Nihon Kohden EEG systems, offers individually configured report templates, including adaptive auto text functions, for fast and simple reporting. It guarantees maximum flexibility and compatibility. Technical Specifications: Routine EEG composition: Electroencephalograph: EEG-1200J/K PC unit: CC-120AJ/AK Electrode junction box: JE-921A Flash lamp assembly: LS-703A Photic stimulator control unit: LS-120AJ/AK Cart: KE-122A Stand: KC-001A LCD display: Local purchase EMU Composition: Electroencephalograph: EEG-1200J/K PC unit: CC-120AJ/AK 256 channel electrode junction box: JE-120A-256 Input box converter: QI-123A Mini flat junction box: JE-125AK Mini flat junction box: JE-226AK Mini flat junction box: JE-227AK Mini flat junction box: JE-228AK Flash lamp assembly: LS-703A Photic stimulator control unit: LS-120AJ/AK Cart with printer table: KD-029A Stand: KC-001A LCD display: Local purchase Extension unit: MS-120BK Switch box: PE-210AK Model Suffixes EEG-1200 has the following suffixies: J: 110-127 V AC operation K: 220-240 V AC operation   Click Here To Download Catalogue
    Sku: ZN2023205

    Nihon Kohden Neurofax 1200 Electroencephalogram (EEG) Machine

    Read more
    Quick View
  • Features: Professional EMG/EP operation platform and perfect test items, complete each test in the shortest time. Neuro and muscle navigation system, convenient in selecting test part. Powerful normal values system, contrast with normal data automatically. Flexible software design, configure system parameters according to requirements. High-speed data collection, electromagnetic interference suppression, Photoelectric isolation and low noise. Integrative hardware system, compact in configuration and easy in moving. Performance: Main system part A/D conversion resolution 16 Bit Sampling ratio 200kHz Analysis time 5-5000ms Stimulating frequency 0.1-50Hz Amplifier part Four-channel Sensitivity 0.05μ V-20mV/Grid Earth noise EMG <= 4μ V(Vpp) EP = 100dB 50Hz Ban wave setting Upper limit for Filter-frequency 20kHz Lower limit for Filter-frequency 1Hz Gain amplifies 25 times-400000 times Stimulator part Constant current 0.2-100mA Pulse width 50-1000μ S Short circuit and overloading protection Auditory Stimulator Stimulation wave 40Hz Short, Sound Stim Stimulation polarity nondense wave, dense wave and alternant wave. Sound strength 40-120db (5db per level) Stimulation mode left, right, left & right Frequency of 40Hz carrier wave 500-8000Hz Visual stimulator Mode tessellation, horizontal bar and vertical bar. Stimulation view all-view, half-view and quarter-view Resolution 3×4, 6×8, 12×16, 24×32, 48×64 Flash stimulator all quench, left light, right light, l&r light   Accessories: Disk Power Cord Power Adapter USB Cable Audio Cable Earth Cable Current Stimulator One-off Bipolar Needle Electrode D039035408, 0.35*40mm, D039060706, 0.60*70mm Reuseable Bipolar Needle Electrode R039035408, 0.35*40mm, R039060706, 0.60*70mm Concentric Needle Connecting Wire 1mm Connecting Lead Wire Disc Electrode Ring Electrode Surface Electrode Ground Electrode(Include lead cable) One-off Unipolar Needle Electrode From 1 to 2 Conversion Cable Surface Electrode Conversion Cable Fuse 0.1A/250V, 5*20mm Fuse F1.6AL250V, 5*20mm Flash Stimulator Audio Stimulator Physical characteristic: Dimension 420mm*350mm*46mm(L× W× H) Net weight 6KG
    Sku: ZN2023206

    Contec CMS6600B Electromyogram (EMG) Machine

    Read more
    Quick View
  • The Neuropack S3 combines Nihon Kohden’s gold-standard amplifiers with time-saving and easy-to-use clinical software, bringing neurodiagnostic labs a feature-rich system that provides cleaner, easier and faster data. The foundation of effective neurodiagnostic testing is a system that can provide a full complement of neurodiagnostic tests while also offering the quality needed to analyze and monitor nervous system function. Features: State-of-the-art low-noise amplifier with 18-bit A/D converters and artifact-reduction software provides clean waveforms Built-in rejection ratios of 110 dB or greater (differential mode) and 112 dB or greater (isolation mode) limit variations in signals Electrode input impedance of 200 MΩ ±20% helps ensure clean signals On-screen examination guide directs electrode and stimulation placement for smooth and efficient examinations HL7® gateway integration helps ensure quick flow of information and streamlines workflow Intuitive control panel and stimulators aid in acquiring and progressing through studies Customizable protocols shorten examination time One-click report generation produces print-ready reports with customized logos, test results, exam waveforms and highlighted abnormal values Proprietary all-in-one NCS program performs MCS, SCS and F-wave for quick examinations Customized auto-copy settings allow waveforms to be stored and automatically transferred to long-term storage   Technical Specifications: Main unit: DC-960B Electrode junction box, 2 or 4 ch: JB-962B or JB-964B Control unit, desktop: GG-961BK Power supply: SC-230BK Cart: KD-026A Arm: KH-960A Holder: DI-961B Somato control box: RY-960B LCD display: Local purchase Printer: Local purchase Number of channels: 2 or 4 Input impedance Common mode: >100 MΩ Differential Mode: >200 MΩ CMRR Differential Mode: >106 dB Isolation Mode: >112 dB Noise level: 0.6 μVrms Sampling Resolution: 18 bit Sensitivity: 1 to 500 μVrms/div., and 1 to 10 mVrms/div. Low-cut filter: 0.01 Hz to 3 kHz High-cut filter: 10 kHz to 20 kHz Analysis time base: 0.1 ms/div to 1 s /div Model Suffixes EEG-1200 has the following suffixies: J: 110-127 V AC operation K: 220-240 V AC operation   Click Here To Download Catalogue
    Sku: ZN2023207

    Nihon Kohden Neuropack S3 Electromyogram (EMG) Machine

    Read more
    Quick View
  • Hot
    Various Frequency option 2MHz or 3MHz is available upon request. (200T:3MHz) Waterproof probe Even the most basic Doppler has waterproof probe suitable for water delivery. (IPX7) Complimentary carrying pouch All handheld Doppler comes with carrying pouch FHR and sound management Dedicated PC software enables save and manage FHR and heart sound data. It indicates FHR as numeral by irradiating ultrasound at the abdomen. It is CE, FDA & FSC certified. The main unit has 6 hours of operating time. It works with Rechargeable battery. And includes 3.5mm earphone jack. Click Here To Download Catalogue
    Sku: ZN2023208

    Bistos BT-200 Fetal Doppler

    Read more
    Quick View
  • Outputs Loudspeaker 350mW rms typical Headset 10mW total (32 Omega stereo headset) Fetal Health Rate Display 3 digit FHR, Pulse/Signal quality Battery Low Accuracy <+ 2 bpm over 100-180 bpm Unique design Easy to use Water proof probe as standard Fetal Heart Rate Display
    Sku: ZN2023209

    SONICAID

    Read more
    Quick View
  • Pinard Fetal Stethoscopes A Professional Produc High Quality
    Sku: ZN2023210

    Pinard Aluminum & Plastic Foetoscope

    Read more
    Quick View
  • Hot
    A practical way to reduce the exposure of pregnant women to ultrasound – listen to the baby”s heartbeat with Pinard Stethoscope, part of the midwife”s basic equipment. Advantages: You are hearing this baby”s heart beating with your own ears and not the ultrasound Doppler effect converted by technology back into sound. What you are hearing is direct; it is not computed or averaged by a hand-held Doppler or a CTG. Several people do not wish any ultrasound to be used, unless there is a clear indication 3) Much more economical than other conventional alternatives.
    Sku: ZN2023211

    Plastic Fetoscope

    Read more
    Quick View
  • Features of Temperature and Humidity Meter:  It has a Large LCD display, multi-function. It displays Indoor & outdoor temperature display, indoor humidity display, and time display. It shows Memory of MAX & MIN measuring value. It displays 12 hours/ 24-hour displaying system selectable. It also displays temperature is degree C & F unit selectable. It has features of Clock, Date & Calendar function (month and date). It has an Everyday alarm function. It displays as Desk-top placing or Wall Hanging. It has low power consumption. It has High stability & accuracy.
    Sku: ZN2023212

    Temperature and Humidity Meter HTC-2 Hygrometer HTC2

    Read more
    Quick View
  • AQ-100 equipped with high-resolution module (1280*1024) and CBI capabilities to provide the best possible image quality for endoscopes. Enhancing the observation of capillaries and mucosal issues. (HBE) Hemoglobin enhancement (CBI) Compound Band Imaging Fully digital AQ SYSTEM processor Electronic magniication (ENH) Outline enhancement
    Sku: ZN2023213

    AOHUA Aq100 Imaging System

    Read more
    Quick View
  • To provide image processing functions and igure and blood vessels enhancement functions which increases e ciency of clinical diagnosis of diseases. Auto White balance adjustment function.Image brightness and color adjustment function. Images frozen and picture in picture function.Figure and Blood vessels enhancement function. Peak and average metering light Shift function. DVI Digital Signal Blood Vessels Enhancement 150W Xenon Lamp
    Sku: ZN2023214

    AOHUA VME-2800 Imaging System

    Read more
    Quick View
  • Auto Power Of & Illuminated display 3-in-1 temperature measurement | display in F or C 25 memory locations Contact less temperature measurement with infrared Quick 1-second measurement with beep Ergonomic design
    Sku: ZN2023215

    CA-MI Infrared No Touch

    Read more
    Quick View
  • Dräger Jaundice Meter JM-105 is a non-invasive transcutaneous bilirubinometer that measures the yellowness of subcutaneous tissue in newborn infants as young as 24 weeks gestational age who have not undergone a transfusion or phototherapy. The Dräger Jaundice Meter JM-105 gives you consistent quality, cost effectively delivered over the lifetime of the device. Features: Effective Jaundice Screening With the Dräger Jaundice Meter JM-105 you can accurately identify at-risk infants as young as 35 weeks gestational age. Effective screening can decrease readmission rates and durations of stay. Having dependable results in seconds rather than hours increases patient safety and expedites decision making. New integrated flagging feature helps you keep track of patients in need of special attention and comply with your jaundice management protocols. Easy to use, easy on everyone The Dräger Jaundice Meter JM-105 expands the concept of ease of use. It also means an easier experience for all involved. Since there’s no blood draw, there’s less stress on fragile new-borns and their parents – which makes things easier on you. Screening with this device is fast and easy; simply clean the reusable tip with an alcohol wipe and take your measurement. No fumbling with disposable tips. No recalibration with every baby. Finally, the device makes it easy for you to get the information you need because it eliminates waiting for laboratory results. And because the device connects to your hospital information system, transferring jaundice screening information to the infant’s electronic medical record is effortless and accurate. Simply put, the device is gentle for the new-born and efficient for you. Improved process and cost efficiency The Dräger Jaundice Meter JM-105 streamlines jaundice screening practices by eliminating time-consuming blood draws, scheduling of laboratory work, and processing costs. It improves efficiency by delivering reliable measurements with significantly fewer steps, which frees up more time for direct infant care. The data transfer functionality and barcode scanner help you optimise your screening program and reduce the risk of human error. Because it has a reusable probe tip, it requires no disposables. With the volume of screenings performed in nurseries today, the cost of such disposable items can ultimately exceed the initial cost of the device itself. As a result, you save time and money while delivering an exceptional standard of care with Dräger Jaundice Meter JM-105   Click Here To Download Catalogue
    Sku: ZN2023216

    Dräger Jaundice Meter JM-105

    Read more
    Quick View
  • Hot
    Jaundice is one of the most common symptoms in the neonatal period. Clinical reports show that 20% to 30% of newborns may have visible jaundice. And early neonatal pathological jaundice is prone to bilirubin encephalopathy, so it is important to screen for early pathological jaundice. DHD-C Percutaneous Jaundice Meter physical sample and advantages Large LCD display Two units displayed at the same time Average value display, more storage Lithium battery, long standby time Continuous measurement, no need to reset Technical Parameters: Measurement meth: light reflective Light source: LED Display: LCD Indication error: 0~25 mg/ dL ± 1.0 mg/ dL Power supply: Lithium battery (DC3.6V, 1000mAh ± 20%);Tests can be done more than 800 times after a fully charge; Calibration color screen: white end face is 0, yellow end face is 16.0±1.0 Function Simultaneous display of measurement units: displaying mg / dL & µmol / L in the meantime. Data Storage: 200 groups of measurement data Average Calculation: It can measure the average value of 2-5 times Start-up preparation time: Ready to use at startup, no preparation required Battery voltage detection function: When the battery voltage of the tester is too low, the screen displays “Low Battery” Automatic shutdown: Automatic shutdown after 10 minutes of non-working state Battery display: Real-time display of battery power Charging display: The viewing screen shows “Charging … ” during charging. Automatic charging protection: It will stop charging automatically at the time battery voltage charging arrive 4.2V±0.05V. Click Here To Download Catalogue
    Sku: ZN2023217

    Heal Force Percutaneous Jaundice Meter DHD-C

    Read more
    Quick View
  • Hot
    Color: Blue The outer diameter of the lancet: 28G Packing: 50 Pieces
    Sku: ZN2023218

    Lancet Pack

    Read more
    Quick View
  • Quality laryngoscopes with vacuum illumination convince through their interesting cost effectiveness due to an almost unlimited service life Well thought-out design guarantees simple handling in daily use.
    Sku: ZN2023219

    Riester Laryngoscopes

    Read more
    Quick View