Zenrox offers cutting-edge medical equipment and comprehensive support services in Lagos. Explore our products designed for superior healthcare delivery. Contact us today for innovative medical solutions.
A single, Integrated Point-of-care testing solution
The i-STAT handheld accelerates the patient care decision-making process with a system that makes patient-side testing fast, easy and accurate. The i-STAT handheld operates with the advanced technology of single-use i-STAT test cartridges. Together, they create the i-STAT System*—a blood analysis system that provides health care professionals with the information they need to rapidly make treatment decisions, which may lead to enhanced quality of care and improved system efficiency.
Benefits and features of the i-STAT System:
Lab-quality results fast: Only four steps needed to get important results in less time and at less cost
Simple to use: Clear and comprehensive instructions help operator through testing process
Broad test menu: Single-use i-STAT test cartridges cover a large menu of testing options in one platform
Comprehensive support: 24/7
technical support ensures that the i-STAT System is supported at all times
Four easy steps to blood analysis – at the patient’s side
Patient-side testing with the i-STAT System is as easy as inserting 2 or 3 drops of blood into the cartridge, inserting the cartridge into the handheld, and then viewing test results in as little as 2 minutes for most cartridges. Test results are uploaded automatically, delivered wirelessly with the i-STAT Wireless or directly when the i-STAT handheld is placed in a downloader. The i-STAT System eliminates process steps and handoffs to help reduce the incidence of errors and promote patient safety.
Patient-centred care for improved patient satisfaction
The i-STAT System allows health care teams to stay with-patient during testing to deliver collaborative, patient-centred care. The system drives performance and efficiency at each stage of the patient journey, from the time spent waiting to be seen through to treatment, discharge or admission.
i-STAT SYSTEM Helps health care professionals:
Reduce potential for errors
Promote collaboration among clinical teams, allowing for consultation with colleagues to make immediate treatment decisions at the bedside
Quickly respond to any need or change in a patient’s condition
Interact with the patient’s family, without leaving the patient’s side and increase family involvement and confidence
As a result, the i-STAT System can enhance patient satisfaction by minimising wait times and length of stay
Click To Download Catalogue
Accurate and Efficient ,Up to 500 tests/hour for medium/large volume sample testing. Test categories include Routine, STAT, and QC
Easy to Operate
Large touchscreen LCD offers simple menu navigation
Convenient
Automatic calibration and waste disposal reduce hands-on time Can read strips with up to 14 parameters, including Microalbumin/Creatinine/Calcium Strip selection of up to 4 combinations for analyzer reading
Data Management Capability
RS232C port for easy data transfer to an external computer or LIS Record Operator/Patient ID by manual entry or Barcode Reader
Unique Lockout Functions
Strip Lockout
User Lockout
QC Lockout
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface.
Features:
Parameters: Na+,K+,Cl-, iCa++ / Li
It works on ISE principle
Sample Type: Whole blood, Serum, Plasma, Urine
Low reagent consumption
Sample requirement is only 90ul
60 samples per hour
Automatic two point calibration after 4hrs and one point calibration with each sample analysis
Air bubble detection
Track reagents consumption and provides alerts
For low reagent volume
Precision testing facility to get CV and SD
Trilevel Quality Control with LJ plots of last 30days
Low aspiration volume
Fast sample processing
Accurate and Precise results
Technical Specifications:
Parameters
Na+, K+, Cl– /Ca++
Principle
Ion Selective Electrode (ISE)
Sample Type
Analyses whole blood, serum, plasma and urine
Sample Volume
≤100 µL
Analysis Time
≤60 seconds
Throughout
≤60 samples per hour
Data Link
Serial (RS232)
External Interface
USB (Keyboard, Mouse)
Operating Condition
10° C to 35° C, Relative Humidity up to 85%
Storage Condition
Temp: 10° C to 40° C
Relative Humidity
up to 85% non- condensing
Power Supply
100 to 240 VAC ±10%, 50Hz
Dimensions
395 x 260 x 375 mm
Weight
7.5 kg
Click Here To Download Catalogue
The miniiSED is the newest addition to the ALCOR family of Erythrocyte Sedimentation Rate (ESR) analtzer from ALCOR Scientific. The miniiSEd measurement of ESR is fast, accurate and unaffected by variable association with traditional methodologies, such as hematocrit.
Features:
STAT results in only 15 seconds
Fully automated from primary EDTA tubes
100µL sample volume
No exposure to patient sample
Ideal compact size
High correlation to Westergren method
Easily interfaces to LIS
Technical Specification:
Principle of Measure: Photometrical rheoscope
Analytical Range: 1-130 mm/hr
Sample Requirements: 100µL whole blood (500µL dead volume)
Tube Requirements: 13 x 75 mm, test tube in EDTA anti-coagulant, capped
Quality Control: Barcoded Seditrol QC
Barcode Reader: Internal
Interface Specifications: RJ-45 Ethernet for LIS connection
Weight: 4.445 kgs / 9.8 lbs
Dimensions (H x W x D): 24 x 18 x 26 (cm) /9.5 x 7.1 x 10.4 (in)
Voltage: 100-240VAC
Frequency Range: 50-60 Hz
Power: 60W
Click Here To Download Catalogue
The Eclipse A1c offers a fast and easy way to measure HbA1c in a physician’s office setting or long term care facility where speed and convenience counts most. HbA1c can be measured in just 3 simple steps and the result is certified by National Glycohemoglobin Standardization Protocol (NGSP) to ensure accuracy.
Key Features
1. Method: Immunoassay
2. Measurement Range (mg/dL): 4-14% HbA1c
3. Sample Volume: 1μL
4. Analysis time: 5 minutes
5. Memory Capacity: 500 tests with date and time
6. Light Source: LED
7. Power supply: Switching power adapter 6V 2A
8. Interface: USB/printer port
9. Precision: CV 0.5 µL
Weight (g) without Batteries: 1200g
Memory Capabilities: 250 memory sets with date and time
Data Output: Dedicated port for printer, USB and optional barcode scanner
Dimension (mm): D248mm x W162mm x H95mm
Click Here To Download Catalogue
The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
User-friendly: the LabPad® INR is designed to be easy to use especially thanks to its 3D-shaped microcuvette that only requires a small drop of blood from a fingertip. Thanks to the color screen, both measurement steps and browsing the list of results are easy to visualize.
Quick and reliable: the reliability of INR results is obtained by quality controls that are performed automatically before each measurement. In less than one minute, you can see if you are in your therapeutic range.
Connected: the result obtained after performing the test can be transferred to healthcare professionals in charge of your treatment monitoring. This result is complementary to the pie charts and trend reports directly displayed on the LabPad® INR to help you monitoring your treatment
Click Here To Download Catalogue
The BC32 Automated Blood Culture Systems are designed to accurately detect and recover microorganisms from blood and normally sterile body fluids (SBF). Runtime detection and sophisticated algorithms minimize false negatives and shorten time to positive detection.
More Compact
More Cost-Effective
More Easily Controlled
Features:
Capacity: 32 Culture Bottle
Equipped with built-in computer and touch screen
Barcode scanning input
Colorimetric technology
Designed to detect microbial from blood specimen or sterile body fluid
Automated continuous monitoring for every 10 minutes for each bottle by independent detection sensor
Real-time display od incubation temperature and reaction chart
Flexible and quick historical data query and statistic functions
Operating Temp: 5~300C
Operating Humidity: <80%%
Voltage: AC100-240V
Click Here To Download Catalogue
This product has a front window operation port, through which the operator can operate inside the safety cabinet. The negative pressure air inhaled from the front window operation port is used to protect the safety of the operator; the downflow filtered by the high efficiency filter is used to protect the experimental articles in the safety cabinet; the air flow filtered by the high efficiency filter is discharged from the safety cabinet to protect the environment.
Features:
LCD large screen
Ergonomic 5 ° inclination design
Backlight design to relieve eyesight fatigue
Platform type hand rest
304 stainless steel liner
Timing function
Easy to clean and disinfect
Technical Specification:
Internal Dimensions (W×D×H) mm: 920×580×655
External Dimensions (W×D×H) mm: 1040×810×2100
Downflow Velocity: 0.33m/s
Inflow Velocity: 0.33m/s
Working Access Opening Height: 200mm
Opening MAX.: 450mm
HEPA Filter Typical Efficiency: 99.99% @ 0.3µm
Noise: 900Lux
Features:
Power on/off switch, more convenient for operation.
UV lamp for disinfection, the interlock function for UV lamp and door.
Microprocessor temperature control, high accuracy sensor, LED display.
High-efficiency refrigeration system, fast cooling speed, and uniform temperature inside.
Double-layer glass observation window, filled with inert gas, to ensure cooling performance.
Audio and visual alarm for high/low temperature, sensor error, power failure, door ajar, low battery.
Technical Specifications:
Model
BJPX-P10
BJPX-P20
Temperature
22±2℃
Accuracy
±0.1 °C
Oscillation
60±5cycles/minute
Amplitude
50mm
Trays
5
10
450ml Blood Bags
Max.10pcs
Max.20pcs
Temp. Control
Microprocessor controller
Display
LCD
Number Of Agitator
Single
Refrigerant
R134a CFC free
Power Supply
AC220V±10%, 50/60Hz
Consumption
101W
180W
Internal Size (W*D*H)mm
427*470*467
607*535*657
External Size (W*D*H)mm
540*605*960
720*670*1150
Package Size (W*D*H)mm
620*660*1050
800*725*1240
Net /Gross Weight
98/130kg
110/150kg
Is a benchtop system which has complete integration in the hematology laboratories by the direct determination of ESR from blood/EDTA samples with its smart and innovative technology combining “ccd cam” and internationally accepted Westergren method.
40 sample loading positions, suitablity to continious loading for 23 minutes when you start running the instrument, being maintanence free, being environment-friendly, LCD touch screen and data transmission to LIS are just some of the advanced features of the analyzer which provides laboratory confort and productivity.
Features:
• Use of the same CBC tubes. No dedicated citrate tube needed
• Westergren method by CCD camera
• Use of smart cards
• No reagents required, environmently friendly
• 40 sample loading positions, up to120 tests/ hour
• Continuous loading of samples untill the first result
• First result available after 24 minutes and each following result within 5 sec.
• 10 inch LCD touch screen
• User friendly software
• Built-in thermal Printer (optional external printer)
• LIS connection
• Optional Barcode reader
Technical Specification:
Principles: Westergren method by CCD Camera
Sample Loading Positions: 40, Direct loading of Blood/EDTA Samples
Throughput: Up to120 samples/hour
Time to First Result: First result in 24 minutes
Time to Result: 5 seconds
Minimum Sample Volume: 2 ml
Sample Test Volume: 2 ml-3 ml
Barcode Reader: External (optional)
Internal Printer: Yes
LIS Communication: Yes
Display: Liquid Touch Screen, 800×600 pixel
Operating Environment: Temperature:15°C-35°C, Humidity: <80%
Power Requirement: A.C. 110-230V <=300 VA 50/60Hz
Dimension: 690mm(L) x425mm(W) x 315mm(H)
Weight: 28 KG
Click Here To Download Catalogue
It is suitable for blood collections in donation room as well as outdoor camps. It ensure smooth & gentle mixing process, volume accuracy, precise monitoring of time & flow rate.
Features:
Unique modern sensor and LED display.
Preset volume of blood collection function.
Soft shaking mode, improves the survival of effective components in the blood.
Shaking auto stops.
Technical Features :
Measuring Range
0~1200ml
Measuring Accuracy
2%
Display Accuracy
1ml
Liquid Proportion
1.05g/ml
Collection Speed
0.5~3ml/s
Swing Frequency
30~32 r/min
Swing Angle
13±2°
Alarm
Audio and visual alarm
Power Consumption
12W
Power Supply
AC110/220V±10%, 50/60Hz
External Size(W*D*H) mm
218*172*160
Packing Size(W*D*H) mm
310*260*210
Net Weight(kg)
2.8
Gross Weight(kg)
4.1
Features and Benefits:
Photoelectric colorimetry
Constant 200 T/H
End Point, Kinetic, Two point
40 sample positions
40 reagent positions
60 reusable reaction cuvette
Specification:
Instrument Performance
Principle:
Photoelectric colorimetry
Assay Method:
End Point, Kinetic, Two point etc.
Throughput:
Constant 200 T/H
Stat Function:
Spesific emergency positions
Sample System
Sample Disk:
40 sample positions include standard, QC, STAT positions
Sample Probe:
High-polished probe, automatical liquid level detection and tracing, collising protection, 2-50µL with 0,1µL increment
Reagent System
Reagent Disk:
40 reagent positions, supporting different type of bottles
Cooling System:
2-8 °C 24h non-stop cooling system
Reagent Probe:
High-polished probe, automatical liquid level detection and tracing, collision protection
Optical System
Light Source:
Halogen-Tungsten lamp with long life, 12V, 20W
Photometry Range:
0-4.0Abs
Wavelength:
9 wavelengths (300nm-700nm)
Reaction System
Reaction Cuvette:
60 reusable reaction cuvette
Washing System:
8-step warm water washing
Min Reaction Volume:
180µL
Heating System:
37±1 °C
Others
Dimension:
415mm (W) x 565mm (L) x 385mm (H)
Weight:
28kg
Water Consumption:
<3L/H
Click Here To Download Catalogue